Functional description

<< Click to Display Table of Contents >>

Navigation:  DEMO Agiator Tank >

Functional description

The mixing container model consists of a tank with a motor-driven agitator M, in which two liquids are mixed together in a predetermined ratio and then heated to a set temperature. The two liquids are supplied via two feed lines, each of which has a coarse valve (V1.1 or V2.1) and a fine valve (V1.2 or V2.2) for exact dosing. The two flow rate sensors QI1 and QI2 generate pulses whose frequency is proportional to the respective filling speed; one pulse corresponds to just 1% of the container volume. The outflow of the mixture is controlled via valve V3. Two limit value transmitters (LIS1/LIS2) and an analog value transmitter (LI1) are available for measuring the fill level. The liquid in the tank can be heated via a heater H; a limit value sensor (TISmax) and an analog value sensor (TI1) are available to measure the temperature. The heater can be switched on both program-controlled and manually via button S2. If the temperature limit value is exceeded, this is signaled by the alarm light H1. The mixing process is started via the start button S1.

 

AgiatorTank_Overview

 

Input/output assignment

The inputs and outputs of the model are assigned as follows (The designation input or output refers to the connected control unit.

refers to the connected control unit):

 

 

Input no.                Name                TwinCat variable name        Description

1                        S1                        I_S1                                        Start button (NO contact)

2                        S2                        I_S2                                        Switch on heating manual button (NO contact)
3                        QI1                        I_QI1                                        Pulses Flow rate sensor left inlet

4                        QI2                        I_QI2                                        Pulses flow rate sensor right inlet

5                        TI1                        I_TI1                                        Analog value transmitter temperature in degrees (100° = 27648)

6                        TISmax                I_TISmax                                Temperature limit value transmitter

7                        LI1                        I_LI1                                        Analog value transmitter level in % (100% = 27648)

8                        LIS1                        I_LIS1                                Lower limit value transmitter level

9                        LIS2                        I_LIS2                                Upper limit value transmitter level

 

 

Output no.                Name                TwinCat variable name        Description

1                        V1.1                        O_V11                                Coarse valve left inlet

2                        V1.2                        O_V12                                Fine valve left inlet

3                        V2.1                        O_V21                                Coarse valve right inlet

4                        V2.2                        O_V22                                Fine valve right inlet

5                        V3                        O_V3                                Outlet valve

6                        H                        O_H                                        Switch on heating

7                        H1                        O_H1                                        Alarm light

8                        M                        O_M                                        Agitator motor