Scenarios where parameters can be included

<< Click to Display Table of Contents >>

Navigation:  Selmo in Use > Flexibilization via parameters >

Scenarios where parameters can be included

The created parameters can be used to make the modeled process more flexible. In the following the usage points are explained and described.

Zone-In and Zone-InOut Inputs

For inputs of Zone-In and Zone-InOut the Input Mode Analog Parameter can be activated, after that the created parameter on which should be compared is selected. The analog input is now compared with the parameter via the selected Input Analog function.

Studio

Studio

 

Zone-InOut and Zone-Out Outputs

For outputs of Zone-InOut and Zone-Out the Output Mode: AnalogParameter can be activated, then the applied parameter to which the analog output should be connected is selected. If the output of the zone is switched out of the sequence, it takes the value of the parameter.

Studio

Studio

 

Time Step

In Time Steps for the definition of the step time a parameter with data type Time must be created and finally selected in Time Step. There is the possibility to let the operator change the parameter or also the possibility to define the parameter as a fixed step time, for this the parameter is hidden in the HMI.

Studio

Studio

 

Driver

Parameters can also be linked to driver modules or are created directly by drivers. The following is an example of an axis driver. A wide variety of drivers can be operated with different parameters, e.g.: Control driver, printer driver, FU driver

Studio

Studio

 

CMZ

Alarm levels can be entered variably via the Expression Mode of the CMZ by means of parameters.

Studio

Studio