In the overview all sequences of the corresponding hardware zone are displayed. Each sequence has its own information window, in which the current step, the status (operating mode, alarm) and the timeout are displayed.

 

The warning sign hmi_lampwarn symbolizes a timeout, a single step and the EOC mode, it indicates that manual intervention is required.

HMI

HMI

Sequence status lamps

Green: The sequence is running in automatic mode.

Red: The sequence has a fault.

Gray: Manual mode is active .

hmi_lamp3

Hardware zone control

HWZControl

 

Lamp test

The lamp test is a standard function and the function of the lamps is checked when the lamp test is carried out. After the button has been clicked, all status lamps used in the sequences (Automatic Lamp, Saftey Gate Lamp, Emergency Stop Lamp and EOC reached Lamp) should light up.

The lamp test can be carried out at the Hardware Zone level and the Plant level. At the Plant level, all lamps light up.

 

LampTest HMI

 

Operating mode Selection

HMIHwzAutomatic

 

Automatic Mode

Automatic mode refers to an operating state in which a system, machine, or device operates automatically without requiring human intervention or control. In Automatic Mode, the system executes preprogrammed sequences, processes, or sequences independently, based on preset parameters, algorithms, or rules. This automates tasks and completes them efficiently without the need for continuous human supervision or intervention.

The green bar indicates that automatic mode has been activated. In this mode, the system operates independently according to preset parameters or rules.

The gray bar indicates that the manual mode has been selected. In this mode, the machine or function can be controlled manually by human intervention.

 

Automatic Release

The "Automatic Release" button enables the release of the "Automatic" mode. When this button is pressed for at least 3 seconds (Adjustable time), the system is set to Automatic mode, which enables it to operate automatically and independently. In this mode, the system executes predefined sequences, sequences or functions without the need for continuous user intervention or instructions.

EOC mode

By activating the "End of Cycle" mode, the sequences are executed until the EOC step and then the automatic operation is stopped.

eoc_mode_hmi

 

Hardware zone status lamps

HMIHwzStatusLamps

 

Any sequences ready to start

Indicates whether a sequence in the hardware zone is ready to start automatic operation.

 

All sequences ready to start

Indicates whether all sequences in the hardware zone are ready to start automatic operation.

 

Automatic Lamp

Flashing indicates that at least one sequence is ready to start.

Continuous light indicates that the automatic mode is active.

 

Safety Gate Lamp

The Safety Gate Lamp indicates whether the Safety Gate switch is activated.

 

Emergency Stop Lamp

The Emergency Stop Lamp signals whether an emergency stop is activated.

 

EOC reached Lamp

The EOC-reached lamp flashes when the EOC mode has been activated.

If the EOC-reached lamp is permanently on, it means that all sequences in the hardware zone have reached the EOC step.

Hardware zone parameters

All parameters defined for the hardware zone are displayed here

HWZ parameter