<< Click to Display Table of Contents >> Navigation: Selmo in Use > Structure plant > Embed step chain (Sequence) |
To embed a step chain in a plant, you must first create the plant. To do this, select the "New Project" option in the "File" context menu and enter a name.
A new Project can be created under File, New Project.
Studio
Select project path and assign a unique name. Each project is created as a Selmo pro-ject (*.seo).
Studio
Next, you need to define the hardware zone where the step chain will be executed.
A hardware zone (HWZ for short) is a specific area of a machine or cell area with separate automatic and manual controls. Each hardware zone has its own specific overview. The size of a hardware zone depends on the configuration of the machine or cell and can contain and control one or more step sequences.
In Selmo Studio, right-clicking on Plant, Add Hardware Zone will add a new machine zone.
Any number of hardware zones can be added to a Plant, but it depends on the performance of the hardware (PLC).
Studio
This creates the following structure:
Studio
Finally, you must add the Sequence, which contains the individual steps of the sequence.
A step chain is called a Sequence and represents a process flow in single steps. You add a Sequence by right-clicking on a HWZ. It is also possible to import or copy a sequence. Each sequence can only be assigned to one hardware zone, but you can assign several sequences to one hardware zone.
Studio
The structure of a Sequence is always the same and consists of several layers as shown in the following picture.
Studio